Home >> Product >> Online Transformer Base UPS >> RB1-10K/B(1-20K)-II

  • RB1-10K &B1-3B20K-Ⅱ
  • RB1-10K &B1-3B20K-Ⅱ
  • RB1-10K &B1-3B20K-Ⅱ
  • RB1-10K &B1-3B20K-Ⅱ
  • RB1-10K &B1-3B20K-Ⅱ
Product name:

RB1-10K &B1-3B20K-Ⅱ

Share

Product parameters

RB1-10K &B1-3B20K-

 

Product Introduce

Reros RB1-10K &B1-3B20K-Ⅱare built on the traditional power frequency uninterrupted power supply concept of sublimation, using IGBT module and output isolation transformer, so that the output of UPS for frequency and voltage stability, filter noise, low distortion, not by the grid fluctuation interference of pure sine wave UPS power supply. The series of products are compact in size, convenient for customers to handle, use, has been widely used in metallurgy, chemical industry, building materials, glass manufacturing, electronics, automobile manufacturing and other fields.

 

 

Main Feature

l1.  Low frequency intelligent, 1/1, 3/1. 

l2.  Concentrated control panel and friendly interface design

l3.  Abundant computer and remote monitoring function

l4.  Cold start function

l5.  N + X parallel redundancy

l6.  Perfect protection function

7.  High performance dynamic and superior load characteristics

 

 

 

 

 

 

Specification

Model

RB1KL(S)

RB2KL(S)

RB3KL(S)

RB6KL(S)

RB10KL(S)

Capacity

1KVA

2KVA

3KVA

6KVA

10KVA

Input

Voltage

220VAC±25%

Frequency

4566Automatic detection and adaptation of 50/60Hz frequency system

Power Factor

≥0.95%

≥0.99%

Output

Voltage

220VAC±1%

Frequency

50H0.5%/60H0.5%(free oscillation)

Distortion Factor

THD<3%Linear Load),THD<5%Non-linear Load

Dynamic response

Full Load±4%

Waveform

Sine Wave

Crest Factor

3:1

Power Factor

0.8

Efficiency

≥92%

≥94%

Battery

Battery Voltage

36V

72V

96V

192V16pcs~20pcscan be adjusted

Battery Type

12V9AH  ×2pcsInternal

12V9AH  ×4pcs

12V9AH  ×6pcs

12V9AH  ×16pcs

12V9AH  ×16pcs

 

Transfer Time

AC fault

0ms

Alarm

AC fault

The alarm sound will stop automatically after 90 seconds every 2 seconds

Battery low voltage

Every 1 second continuous sound, until shutdown, battery LED lights flashing 1s once

UPS Overload

The buzzer went on

Protection

Overload

       110% to 129% switch to bypass after 10 minutes at full load; 130% to 150% switch to bypass after 60 seconds at full load and automatically restore inverter output

Display

LED

The state indicated by the LED lightAC Input/Bypass/Inverter/Battery/Overload/Fault

LCD

Input voltage/Output voltage/Battery voltage/Frequency/load percent/UPS work status

Others

Temperature()

0℃—40

Humidity

0%—95%No condensing

Noise(dB)

<58dBwithin 1 meter

Weight(Kg)

20/29

26/48

30/50

60/96

63/99

SizeW×D×Hmm

440×600×220(5U)

440×800×360(8U)

 

Specification

Model

B1KL(S)-II

B2KL(S)-II

B3KL(S)-II

B/3B6KL(S)-II

B/3B10KL(S)-II

B/3B15K-II

B/3B20K-II

Capacity

1KVA

2KVA

3KVA

6KVA

10KVA

15KVA

20KVA

Input

Voltage

220VAC±25%

220/380VAC±25%

Frequency

4566Automatic detection and adaptation of 50/60Hz frequency system

Power Factor

≥0.95%

≥0.99%

Output

Voltage

220VAC±1%

Frequency

50HZ±0.5%/60HZ±0.5%(free oscillation)

Distortion Factor

THD<3%Linear Load),THD<5%Non-linear Load

Dynamic response

Full Load±4%

Waveform

Sine Wave

Crest Factor

3:1

Power Factor

0.8

Efficiency

≥90%

≥92%

Battery

DC Voltage

36V

72V

96V

192V

Battery Type

12V9AH  ×2pcs

12V9AH  ×4pcs

12V9AH  ×6pcs

12V9AH  ×16pcs

External

Transfer Time

AC fault

0ms

Alarm

AC fault

The alarm sound will stop automatically after 90 seconds every 2 seconds

Battery low voltage

Every 1 second continuous sound, until shutdown, battery LED lights flashing 1s once

UPS overload

The buzzer went on

Protection

Overload

       110% to 129% switch to bypass after 10 minutes at full load; 130% to 150% switch to bypass after 60 seconds at full load and automatically restore inverter output

Display

LED

The state indicated by the LED lightAC Input/Bypass/Inverter/Battery/Overload/Fault

LCD

Input voltage/Output voltage/Battery voltage/Frequency/load percent/UPS work status

Others

Temperature()

0℃—40℃

Humidity

0%—95%No condensing

Noise(dB)

<58dBwithin 1 meter

Weight(Kg)

17/22

27/40

28/41

60/105

65/110

95

105

SizeH×W×D)mm

368×145×349

498×190×390

786×240×503(L)

955×248×502

786×425×503(S)

 

 

RB1-10K

RB1-10K

RB1-10K

FAQ                                                                                                 

1)What is your minimum order quantity?

A: For common specification, there is no minimum order quantity, and one piece could also be supplied. The difference is just the price and schedule. If your request is some special, we need to calculate it accordingly.


2)Is OEM/ODM available?

A: Yes, it is! Our products can be Customized. We have 5 senior engineers in our R&D Dept.


3)What is the Terms of Payment?

A: T/T, L/C, D/P, D/A, Western Union, Paypal and MoneyGram (for Small-amount payment).


4)Can you offer Form A or Form E or C/O?

A: Yes, it's no problem, we could apply it from our local government.


5)What's the warranty condition for your UPS?

A: 1 year warranty after the shipment of boarding date, and 1% single phase of UPS amount by free Spare Parts shipped together with each order shipment;


6)How is your delivery time?

A: It depends on your order quantity and specification,  usually about 7~20days, and it won't cost more than 35days


7)What are the advantages of your company?

A: Reros has about 30 years manufacturing experience, and more than 20 years exporting experience. We promise your quality and service all the time. Adequate inventory, and supply guarantee for the subsequent renewal of supply, providing different solutions.