RB1-10K &B1-3B20K-Ⅱ
Product Introduce
Reros RB1-10K &B1-3B20K-Ⅱare built on the traditional power frequency uninterrupted power supply concept of sublimation, using IGBT module and output isolation transformer, so that the output of UPS for frequency and voltage stability, filter noise, low distortion, not by the grid fluctuation interference of pure sine wave UPS power supply. The series of products are compact in size, convenient for customers to handle, use, has been widely used in metallurgy, chemical industry, building materials, glass manufacturing, electronics, automobile manufacturing and other fields.
Main Feature
l1. Low frequency intelligent, 1/1, 3/1.
l2. Concentrated control panel and friendly interface design
l3. Abundant computer and remote monitoring function
l4. Cold start function
l5. N + X parallel redundancy
l6. Perfect protection function
7. High performance dynamic and superior load characteristics
Specification
Model | RB1KL(S) | RB2KL(S) | RB3KL(S) | RB6KL(S) | RB10KL(S) | ||
Capacity | 1KVA | 2KVA | 3KVA | 6KVA | 10KVA | ||
Input | Voltage | 220VAC±25% | |||||
Frequency | 45~66(Automatic detection and adaptation of 50/60Hz frequency system) | ||||||
Power Factor | ≥0.95% | ≥0.99% | |||||
Output | Voltage | 220VAC±1% | |||||
Frequency | 50HZ±0.5%/60HZ±0.5%(free oscillation) | ||||||
Distortion Factor | THD<3%(Linear Load),THD<5%(Non-linear Load) | ||||||
Dynamic response | Full Load±4% | ||||||
Waveform | Sine Wave | ||||||
Crest Factor | 3:1 | ||||||
Power Factor | 0.8 | ||||||
Efficiency | ≥92% | ≥94% | |||||
Battery | Battery Voltage | 36V | 72V | 96V | 192V(16pcs~20pcs,can be adjusted) | ||
Battery Type | 12V9AH ×2pcs(Internal) | 12V9AH ×4pcs | 12V9AH ×6pcs | 12V9AH ×16pcs | 12V9AH ×16pcs
| ||
Transfer Time | AC fault | 0ms | |||||
Alarm | AC fault | The alarm sound will stop automatically after 90 seconds every 2 seconds | |||||
Battery low voltage | Every 1 second continuous sound, until shutdown, battery LED lights flashing 1s once | ||||||
UPS Overload | The buzzer went on | ||||||
Protection | Overload | 110% to 129% switch to bypass after 10 minutes at full load; 130% to 150% switch to bypass after 60 seconds at full load and automatically restore inverter output | |||||
Display | LED | The state indicated by the LED light,AC Input/Bypass/Inverter/Battery/Overload/Fault | |||||
LCD | Input voltage/Output voltage/Battery voltage/Frequency/load percent/UPS work status | ||||||
Others | Temperature(℃) | 0℃—40℃ | |||||
Humidity | 0%—95%(No condensing) | ||||||
Noise(dB) | <58dB(within 1 meter) | ||||||
Weight(Kg) | 20/29 | 26/48 | 30/50 | 60/96 | 63/99 | ||
Size(W×D×H)mm | 440×600×220(5U) | 440×800×360(8U) |
Specification
Model | B1KL(S)-II | B2KL(S)-II | B3KL(S)-II | B/3B6KL(S)-II | B/3B10KL(S)-II | B/3B15K-II | B/3B20K-II | |
Capacity | 1KVA | 2KVA | 3KVA | 6KVA | 10KVA | 15KVA | 20KVA | |
Input | Voltage | 220VAC±25% | 220/380VAC±25% | |||||
Frequency | 45~66(Automatic detection and adaptation of 50/60Hz frequency system) | |||||||
Power Factor | ≥0.95% | ≥0.99% | ||||||
Output | Voltage | 220VAC±1% | ||||||
Frequency | 50HZ±0.5%/60HZ±0.5%(free oscillation) | |||||||
Distortion Factor | THD<3%(Linear Load),THD<5%(Non-linear Load) | |||||||
Dynamic response | Full Load±4% | |||||||
Waveform | Sine Wave | |||||||
Crest Factor | 3:1 | |||||||
Power Factor | 0.8 | |||||||
Efficiency | ≥90% | ≥92% | ||||||
Battery | DC Voltage | 36V | 72V | 96V | 192V | |||
Battery Type | 12V9AH ×2pcs | 12V9AH ×4pcs | 12V9AH ×6pcs | 12V9AH ×16pcs | External | |||
Transfer Time | AC fault | 0ms | ||||||
Alarm | AC fault | The alarm sound will stop automatically after 90 seconds every 2 seconds | ||||||
Battery low voltage | Every 1 second continuous sound, until shutdown, battery LED lights flashing 1s once | |||||||
UPS overload | The buzzer went on | |||||||
Protection | Overload | 110% to 129% switch to bypass after 10 minutes at full load; 130% to 150% switch to bypass after 60 seconds at full load and automatically restore inverter output | ||||||
Display | LED | The state indicated by the LED light,AC Input/Bypass/Inverter/Battery/Overload/Fault | ||||||
LCD | Input voltage/Output voltage/Battery voltage/Frequency/load percent/UPS work status | |||||||
Others | Temperature(℃) | 0℃—40℃ | ||||||
Humidity | 0%—95%(No condensing) | |||||||
Noise(dB) | <58dB(within 1 meter) | |||||||
Weight(Kg) | 17/22 | 27/40 | 28/41 | 60/105 | 65/110 | 95 | 105 | |
Size(H×W×D)mm | 368×145×349 | 498×190×390 | 786×240×503(L) | 955×248×502 | ||||
786×425×503(S) |
FAQ
1)What is your minimum order quantity?
A: For common specification, there is no minimum order quantity, and one piece could also be supplied. The difference is just the price and schedule. If your request is some special, we need to calculate it accordingly.
2)Is OEM/ODM available?
A: Yes, it is! Our products can be Customized. We have 5 senior engineers in our R&D Dept.
3)What is the Terms of Payment?
A: T/T, L/C, D/P, D/A, Western Union, Paypal and MoneyGram (for Small-amount payment).
4)Can you offer Form A or Form E or C/O?
A: Yes, it's no problem, we could apply it from our local government.
5)What's the warranty condition for your UPS?
A: 1 year warranty after the shipment of boarding date, and 1% single phase of UPS amount by free Spare Parts shipped together with each order shipment;
6)How is your delivery time?
A: It depends on your order quantity and specification, usually about 7~20days, and it won't cost more than 35days
7)What are the advantages of your company?
A: Reros has about 30 years manufacturing experience, and more than 20 years exporting experience. We promise your quality and service all the time. Adequate inventory, and supply guarantee for the subsequent renewal of supply, providing different solutions.